HUEBERT FIBERBOARD ROOF INSULATION THERMAL CONDUCTANCE
EQUIVALENTS

THICKNES

CONDUCTANCE

RESISTANCE

1/2"
3/4"
1"
1 1/2"
2"
2 1/2"
3"

.72
.48
.36
.24
.19
.15
.12

1.38
2.08
2.78
4.17
5.26
6.67
8.33



HUEBERT FIBERBOARD ROOF INSULATION SPAN STRENGTHS 

  UNSUPPORTED
CHANNEL WIDTH

MINIMUM
BOARD THICKNESS 

UP TO 3/4"
3/4"TO 1 1/2"
1 1/2" TO 2 5/8"
2 5/8" TO 3 1/2"
3 1/2" TO 4 1/4"

1/2"
3/4"
1"
1 1/2"
2" (
APPLIED IN TWO 1" PLIES, STAGGERED.)
1"
OR GREATER
ACCEPTED BY
FACTORY MUTUAL

HUEBERT FIBERBOARD ROOF INSULATION COMPLIES WITH STANDARDS FOR FIBERBOARD SET FORTH IN: FEDERAL--LLL-1-535-B CLASS C * COMMERCIAL STANDARD (U.S. DEPT. OF COMMERCE) PS57-73 ASTM--C-20895  FACTORY MUTUAL CLASS 1   CONSTRUCTION -

 

 

 

Roof_Insulation_Board

Coated High Density Roof Insulation

 

Huebert Fiberboard Roof  Insulation Thermal Conductance Equivalents

History & information about
Huebert Fiberboard

U-Values for Various Deck Construction and Thickness of Huebert fiberboard Roof Insulation

Compression Test Results

Back to Home Page

Huebert Fiberboard Archery


     Hit Counter                                                       Phone 660-882-2704 or 800-748-7147  

  E-MAIL sales@huebertfiberboard.com